- Reverted back the serial RX count function to how it was. The variable type was unsigned and cause an integer underflow whenever the calculation produced a negative number. The old way was the correct way. - Lots of minor edits to the code CSVs and markdown documents. - Expanded on explaining feedback messages and startup line execution feedback. - Created a new settings codes CSV to help GUIs import the values and meanings.
10 lines
1.1 KiB
CSV
10 lines
1.1 KiB
CSV
(KEY: Alarm Code in v1.1+, Alarm Message in v1.0-, Alarm Description)
|
|
1,Hard limit,Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended.
|
|
2,Soft limit,Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked.
|
|
3,Abort during cycle,Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended.
|
|
4,Probe fail,Probe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered.
|
|
5,Probe fail,Probe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4.
|
|
6,Homing fail,Homing fail. The active homing cycle was reset.
|
|
7,Homing fail,Homing fail. Safety door was opened during homing cycle.
|
|
8,Homing fail,Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring.
|
|
9,Homing fail,Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring.
|