1,Expected command letter,G-code words consist of a letter and a value. Letter was not found.
|
|
2,Bad number format,Numeric value format is not valid or missing an expected value.
|
|
3,Invalid statement,Grbl '$' system command was not recognized or supported.
|
|
4,Value < 0`,Negative value received for an expected positive value.
|
|
5,Setting disabled,Homing cycle is not enabled via settings.
|
|
6,Value < 3 usec,Minimum step pulse time must be greater than 3usec.
|
|
7,EEPROM read fail. Using defaults,EEPROM read failed. Reset and restored to default values.
|
|
8,Not idle,Grbl '$' command cannot be used unless Grbl is IDLE. Ensures smooth operation during a job.
|
|
9,G-code lock,G-code locked out during alarm or jog state.
|
|
10,Homing not enabled,Soft limits cannot be enabled without homing also enabled.
|
|
11,Line overflow,Max characters per line exceeded. Line was not processed and executed.
|
|
12,Step rate > 30kHz,Grbl '$' setting value exceeds the maximum step rate supported.
|
|
13,Check Door,Safety door detected as opened and door state initiated.
|
|
14,Line length exceeded,Build info or startup line exceeded EEPROM line length limit.
|
|
15,Travel exceeded,Jog target exceeds machine travel. Command ignored.
|
|
16,Invalid jog command,Jog command with no '=' or contains prohibited g-code.
|
|
20,Unsupported command,Unsupported or invalid g-code command found in block.
|
|
21,Modal group violation,More than one g-code command from same modal group found in block.
|
|
22,Undefined feed rate,Feed rate has not yet been set or is undefined.
|
|
23,Invalid gcode ID:23,G-code command in block requires an integer value.
|
|
24,Invalid gcode ID:24,More than one g-code command that requires axis words found in block.
|
|
25,Invalid gcode ID:25,Repeated g-code word found in block.
|
|
26,Invalid gcode ID:26,No axis words found in block for g-code command or mode which requires them.
|
|
27,Invalid gcode ID:27,Line number value is invalid.
|
|
28,Invalid gcode ID:28,G-code command is missing a required value word.
|
|
29,Invalid gcode ID:29,Work coordinate system commanded not supported.
|
|
30,Invalid gcode ID:30,G53 only allowed during G0 and G1 motion modes.
|
|
31,Invalid gcode ID:31,Axis words found in block while no command uses them.
|
|
32,Invalid gcode ID:32,G2/3 arcs require at least one in-plane axis word.
|
|
33,Invalid gcode ID:33,Motion command target is invalid.
|
|
34,Invalid gcode ID:34,Arc radius value is invalid.
|
|
35,Invalid gcode ID:35,G2/3 arcs require at least one in-plane offset word.
|
|
36,Invalid gcode ID:36,Unused value words found in block.
|
|